Skip to main content
. Author manuscript; available in PMC: 2022 Sep 19.
Published in final edited form as: Biomed Signal Process Control. 2022 Mar 16;75:103630. doi: 10.1016/j.bspc.2022.103630

Table 6.

The performance of the TAU-Net and its five variants on the collected dataset.

Method Dice
Mean ± SD
IOU
Mean ± SD
SSIM
Mean ± SD
HD
Mean ± SD

TAU-Net 0.9448 ± 0.1189 0.9105 ± 0.1381 0.9521 ± 0.0225 5.4304 ± 1.6943
TAU-Net1 0.9427 ± 0.1239 0.9081 ± 0.1439 0.9521 ± 0.0244 5.4006 ± 1.6841
TAU-Net2 0.9413 ± 0.1252 0.9059 ± 0.1453 0.9505 ± 0.0246 5.3654 ± 1.6850
TAU-Net3 0.9421 ± 0.1288 0.9081 ± 0.1476 0.9521 ± 0.0244 5.4001 ± 1.7190
TAU-Net4 0.9434 ± 0.1236 0.9091 ± 0.1424 0.9520 ± 0.0228 5.4347 ± 1.6849
TAU-Net5 0.9365 ± 0.1402 0.9011 ± 0.1589 0.9502 ± 0.0263 5.4887 ± 1.7679