Skip to main content
. 2022 Mar 9;36(10):7444–7452. doi: 10.1007/s00464-022-09160-7

Table 3.

Recognized result with evaluation dataset

Surgical phase Prediction result (original) Prediction result (postprocessing)
Accuracy Precision Recall Accuracy Precision Recall
P0 0.944 0.903 0.776 0.953 0.938 0.792
P1 0.965 0.779 0.759 0.975 0.830 0.837
P2 0.910 0.919 0.848 0.939 0.930 0.923
P3 0.975 0.586 0.824 0.986 0.745 0.772
P4 0.947 0.802 0.923 0.959 0.824 0.961
P5 0.988 0.507 0.853 0.994 0.802 0.807
P6 0.969 0.785 0.935 0.987 0.915 0.945