Comparison of the whole-cell biosensors constructed in this study to previously reported arsenic whole-cell biosensors.

Host Reporter gene Limit of detection for As (μM) Range of detection for As (μM) Reference
Escherichia coli luxAB 0.09 0.13–1.33 [46]
Escherichia coli gfp 0.067 0.13–2.67 [20]
Escherichia coli egfp 0.13 0–1.33 [3]
Escherichia coli luxCDABE 0.01 0.05–0.80 [42]
Shewanella oneidensis mtrB 40 40–100 [47]
Escherichia coli luxCDABE 0.10 0.05–5.00 [12]
Escherichia coli gfp 0.01 0.013–0.67 [22]
Escherichia coli lacZ 0.13 0.13–6.67 [14]
Escherichia coli egfp 0.033 0.033–0.67 [50]
Escherichia coli mCherry 0.10 0.067–1.87 [19]
Escherichia coli gfp 0.01 0.10–4.00 [5]
Escherichia coli gfp 0.01 0.03–0.1 This study