Skip to main content
. 2022 Sep 21;12:15729. doi: 10.1038/s41598-022-20154-2

Table 4.

Action commands correctly recognized (%) by the Vuzix M400 voice control function at different noise levels (dB) and for different operators.

Operator 65 dB (%) 70 dB (%) 75 dB (%) 80 dB (%) 85 dB (%)
1 100 89 92 3 0
2 100 95 65 0 0
3 97 86 81 0 0
4 100 84 5 0 0
Average 99 89 61 1 0