Skip to main content
. 2022 Sep 22;8(1):e12348. doi: 10.1002/trc2.12348

TABLE 4.

Description of 7 Tesla high field MRI sequences proposed

Sequence Acquisition parameters Measures assessed Time (min)
Set up / localizer GRE Positioning; shimming 5.5
3DT1 MP2RAGE 348 slices (0.55 iso); TR∼6000; TE∼22.54; TI1/2∼800/2500; AF=2 Morphometry; registration; hippocampus segmentation 12.5
3D SWI 208 slices (0.375x0.375x0.75); TR∼24; TE1/2∼8.16/18.35; AF=2 Small vessel analysis; T2* mapping; QSM 9
T2 TSE 36 slices (0.375x0.375x1.5); TR∼10060; TE∼61; AF = 2 Hippocampus segmentation 4
T2 FLAIR 80 slices (0.75x0.75x1.5); TR∼14000; TE∼99; TI∼2900; AF = 2 White matter hyperintensities 11
3D T2 Space 256 slices (0.6 iso); TR∼3400; TE∼367; AF = 3 Morphometry; hippocampus segmentation; perivascular spaces 9.5
MT & non MT 60 slices (0.4 iso); TR=548; TE=4.08; AF = 8 Locus coeruleus intensity; contrast' MT 8
TOF (4 slabs) 192 slices (0.375 iso); TR∼14; TE∼4.5; AF = 3 Angiography; arteriolar analysis 6.5

Abbreviations: FLAIR, fluid‐attenuated inversion recovery; GRE, gradient echo; MT, magnetization transfer; MP2RAGE, magnetization‐prepared 2 rapid acquisition gradient echo; QSM, quantitative susceptibility mapping; SWI, susceptibility weighted imaging; TE, echo time; TOF, time of flight; TR, repetition time; TSE, turbo spin echo.