Skip to main content
. 2022 Sep 8;12(9):2175. doi: 10.3390/diagnostics12092175

Table 4.

Diagnostic Performance of Radiomic Models on Ki-67 level Prediction.

Data Group AUROC Accuracy Sensitivity Specificity
Grayscale Training 0.868 [0.775–0.947] 0.843 [0.771–0.914] 0.860 [0.778–0.931] 0.769 [0.556–0.944]
Testing 0.712 [0.528–0.875] 0.600 [0.567–0.833] 0.710 [0.615–0.893] 0.600 [0.000–0.800]
Kupffer CEUS Training 0.873 [0.763–0.960] 0.786 [0.700–0.871] 0.754 [0.655–0.847] 0.923 [0.778–1.000]
Testing 0.768 [0.621–0.896] 0.700 [0.600–0.867] 0.746 [0.667–0.920] 0.800 [0.500–0.833]
Difference p Training 0.873 0.12 0.069 <0.001
Testing 0.048 0.2 0.834 <0.001

96% Confidence Intervals were included in parenthesis. p-value was calculated with the DeLong test for AUROC comparison and a two-sided permutation test with 10,000 random resamples.