Skip to main content
. 2022 Sep 9;23(18):10434. doi: 10.3390/ijms231810434

Table 1.

Fitting parameters for the relationships between the radiosensitivity endpoints.

Endpoints
Concerned
Fitting
Function
Adjusted a1 Value * Adjusted a2 Value * Adjusted r2 SSE ** RMS ***
SF2 = f(grade) f(x) = a*x + a2 −11.72 (−12.3, −11.15) 61.55 (59.77, 63.32) 0.9805 329.9 3.162
SF2 = f(MN24h) f(x) = a*exp(b*x) 68.55 (62.39, 74.72) −0.1142 (−0.1363, −0.09208) 0.8839 1966 7.719
SF2 = f(H2AX24h) f(x) = a*exp(b*x) 62.56 (57.25, 67.87) −0.2168 (−0.261, −0.1726) 0.8685 2228 8.217
pATMmax = f(grade) f(x) = a1*x + a2 −6.786 (−7.356, −6.215) 41.72 (39.99, 43.45) 0.7399 3912 4.514
SF2 = f(pATMmax) f(x) = a1*x 1.422 (1.322, 1.523) NA 0.8794 1971 7.848

* with 95% confidence bounds; ** SSE: sum squared error; *** RMSE: root mean square error; NA: non-applicable. See also Materials and Methods.