Skip to main content
. 2022 Sep 12;11(18):5351. doi: 10.3390/jcm11185351

Table 2.

Pairwise comparison for extrusion/intrusion.

Sample Comparison Mean (mm) Standard Deviation (mm) p-Value
ClinCheck® Pro–SureSmile® 0.063–0.092 ±0.621–±0.652 0.226
ClinCheck® Pro–Ortho Insight 3D® 0.063–0.136 ±0.621–±0.637 0.026 *
ClinCheck® Pro–Ortho Analyzer® 0.063–0.330 ±0.621–±0.656 0.000 *
SureSmile®–Ortho Insight 3D® 0.092–0.136 ±0.652–±0.637 0.311
SureSmile®–Ortho Analyzer® 0.092–0.330 ±0.652–±0.656 0.000 *
Ortho Insight 3D®–Ortho Analyzer® 0.136–0.330 ±0.637–±0.656 0.000 *

* indicates clinical significance based on p values of ≤0.05.