Table 2.
Pairwise comparison for extrusion/intrusion.
Sample Comparison | Mean (mm) | Standard Deviation (mm) | p-Value |
---|---|---|---|
ClinCheck® Pro–SureSmile® | 0.063–0.092 | ±0.621–±0.652 | 0.226 |
ClinCheck® Pro–Ortho Insight 3D® | 0.063–0.136 | ±0.621–±0.637 | 0.026 * |
ClinCheck® Pro–Ortho Analyzer® | 0.063–0.330 | ±0.621–±0.656 | 0.000 * |
SureSmile®–Ortho Insight 3D® | 0.092–0.136 | ±0.652–±0.637 | 0.311 |
SureSmile®–Ortho Analyzer® | 0.092–0.330 | ±0.652–±0.656 | 0.000 * |
Ortho Insight 3D®–Ortho Analyzer® | 0.136–0.330 | ±0.637–±0.656 | 0.000 * |
* indicates clinical significance based on p values of ≤0.05.