Skip to main content
. 2022 Aug 28;13(9):1419. doi: 10.3390/mi13091419

Table 4.

Fabricated RTD values at different room temperatures, recorded over three months.

Weeks Room Temperature (°C) Avg. Resistance (Ω) Measured Avg. Resistance [Figure 4c] (Ω) Error %
1, 2 25 337 339 0.58
3, 4 30 348 354 1.69
5, 6 36 364 370 1.62
7, 8 40 387 390 0.7
9, 10 42 389 397 2.1
11, 12 45 407 420 3.09