Skip to main content
. 2014 Nov 12;143(9):1964–1971. doi: 10.1017/S0950268814003008

Table 2.

Relationships between blood culture sample sites and BCC (September 2010 to March 2012).

Blood culture sites Blood culture results Relationships between blood culture sample sites and BCC
False positive
n (%)
True positive
n (%)
Negative
n (%)
P value OR (95% CI)
Peripheral venepuncture 30 (34·0) 28 (43·7) 561 (41·3) 0·009 1
Central venous catheter 48 (54·5) 24 (37·5) 431 (31·8) 0·003 2·1 (1·3–3·3)
Dialysis line 5 (5·7) 6 (9·4) 123 (9·1) 0·58 0·7 (0·29–1·99)
Arterial line 3 (3·5) 2 (3·1) 47 (3·4) 0·77 1·2 (0·35–4·1)
Not recorded 2 (2·3) 4 (6·3) 195 (14·4)
Total 88 64 1357

BCC, Blood culture contamination; OR, Odds ratio; CI, confidence interval.