Skip to main content
. 2022 Sep 16;2022:7245384. doi: 10.1155/2022/7245384

Table 2.

Procedural characteristics: PCI target vessels (n = 34).

Vessels planned for treatment, % (n)
 LM, % (n) 32 (11/34)
 LAD, % (n) 29 (10/34)
 LCx, % (n) 18 (6/34)
 RCA, % (n) 21 (7/34)
Number of vessels planned for treatment per patient (±SD) 2.4 (±0.3)
Number of treated vessels, % (n) 88 (30/34)
Number of treated vessels per patient (±SD) 2.1 (±0.3)
Total number of stents implanted 55
Total stent length per patient, mm (±SD) 100 (±16.2)
Number of stents (±SD) 1.6 (±0.2)
Mean stent length, mm (±SD) 25.0 (±1.6)
Mean stent diameter, mm (±SD) 3.2 (±0.1)
Procedural time, min (±SD) 202 (±24)
The contrast used, ml (±SD) 224 (±69)

ECMO, extracorporeal membrane oxygenation; LAD, left anterior descending; LCx, left circumflex; LM, left main; N, number of treated vessels; PCI, percutaneous coronary intervention; RCA, right coronary artery; SD, standard deviation.