Table 1.
Classification results for proposed method using different pre-trained CNNs and PDC images on MAHNOB-HCI database in all frequency bands while using tenfold Cross-Validation method
| Net | Bands | Accuracy (%) | Precision (%) | Recall (%) | F1- score (%) |
|---|---|---|---|---|---|
| AlexNet | Delta | 75.76 ± 0.49 | 75.74 ± 0.56 | 75.78 ± 0.51 | 76.72 ± 0.55 |
| Theta | 76.28 ± 0.52 | 76.25 ± 0.55 | 76.24 ± 0.63 | 76.24 ± 0.50 | |
| Alpha | 78.32 ± 0.63 | 78.30 ± 0.53 | 78.35 ± 0.50 | 78.26 ± 0.67 | |
| Beta | 77.35 ± 0.65 | 77.34 ± 0.56 | 77.36 ± 0.55 | 77.32 ± 0.56 | |
| Gamma | 77.15 ± 0.55 | 77.12 ± 0.50 | 77.16 ± 0.56 | 77.13 ± 0.50 | |
| VGG-19 | Delta | 85.25 ± 0.54 | 85.22 ± 0.50 | 85.26 ± 0.50 | 85.20 ± 0.52 |
| Theta | 85.45 ± 0.58 | 85.75 ± 0.55 | 85.78 ± 0.54 | 85.42 ± 0.55 | |
| Alpha | 87.38 ± 0.46 | 87.33 ± 0.50 | 87.42 ± 0.52 | 87.32 ± 0.52 | |
| Beta | 86.05 ± 0.52 | 86.03 ± 0.53 | 86.10 ± 0.52 | 86.02 ± 0.53 | |
| Gamma | 85.75 ± 0.50 | 85.72 ± 0.40 | 85.78 ± 0.65 | 85.72 ± 0.50 | |
| ResNet-50 | Delta | 93.24 ± 0.53 | 93.23 ± 0.54 | 93.25 ± 0.50 | 93.22 ± 0.52 |
| Theta | 93.64 ± 0.54 | 93.63 ± 0.55 | 93.66 ± 0.54 | 93.61 ± 0.58 | |
| Alpha | 96.26 ± 0.53 | 96.23 ± 0.56 | 96.28 ± 0.55 | 96.23 ± 0.54 | |
| Beta | 94.53 ± 0.52 | 94.52 ± 0.57 | 94.55 ± 0.52 | 94.50 ± 0.55 | |
| Gamma | 94.22 ± 0.51 | 94.16 ± 0.53 | 94.24 ± 0.55 | 94.20 ± 0.50 | |
| Inception-v3 | Delta | 92.10 ± 0.54 | 92.08 ± 0.53 | 92.14 ± 0.55 | 92.07 ± 0.52 |
| Theta | 92.39 ± 0.58 | 92.37 ± 0.50 | 92.42 ± 0.50 | 92.35 ± 0.50 | |
| Alpha | 95.85 ± 0.56 | 95.83 ± 0.54 | 95.87 ± 0.52 | 95.83 ± 0.60 | |
| Beta | 93.29 ± 0.50 | 93.25 ± 0.59 | 93.34 ± 0.56 | 93.26 ± 0.57 | |
| Gamma | 93.07 ± 0.53 | 93.05 ± 0.56 | 93.12 ± 0.55 | 93.05 ± 0.55 |
Highest results are showed bold