Skip to main content
. 2021 Apr 14;197:111149. doi: 10.1016/j.envres.2021.111149

Table 1.

The average results of percentage difference of the number of PM concentration (particle/m3) among untreated air (control) and air treatment using an air pump when compared between 0 and 5 min.

Air pollutant diameter (μm) Percentage difference of the number of PM (particle/m3)
Control
Air pump
Mean Min Max SD Mean Min Max SD
0.3 +12.623 −4.503 +31.546 ±12.226 +0.458 −2.842 +7.686 ±3.230
0.5 +61.539 −29.006 +192.471 ±68.201 +2.533 −12.322 +38.964 ±14.780
1.0 +113.647 −50.142 +421.682 ±133.858 +4.720 −21.637 +56.200 ±22.163
3.0 +19.151 −21.860 +88.520 ±35.764 +9.246 −47.363 +205.550 ±70.238
5.0 +25.847 −38.579 +210.769 ±74.474 +19.449 −59.964 +348.333 ±116.653
10 +9.444 −41.935 +90.000 ±43.976 +28.564 −62.500 +287.273 ±99.019