Skip to main content
. 2021 Apr 14;197:111149. doi: 10.1016/j.envres.2021.111149

Table 2.

The average results of percentage difference of PM mass concentration (mg/m3) among untreated air (control) and air treatment using an air pump when compared between 0 and 5 min.

Air pollutant diameter Percentage difference of PM mass concentration (mg/m3)
Control
Air pump
Mean Min Max SD Mean Min Max SD
PM1.0 +51.098 −16.589 +261.006 ±82.140 +2.784 −12.209 +37.500 ±13.196
PM2.5 +51.167 −16.589 +261.006 ±82.105 +2.860 −12.186 +37.500 ±13.177
PM5.0 +51.049 −16.355 +258.750 ±81.533 +2.902 −11.992 +37.391 ±13.097
PM10 +50.217 −14.685 +258.385 ±81.269 +2.877 −11.753 +37.249 ±13.035
HHS Vulnerability Disclosure