Radiation treatment planning performance measures

3D IMRT
Compliance Mean Std. dev. On‐time Compliance Mean Std. dev. On‐time
Task (%) (days) (days) (%) (%) (days) (days) (%)
CT sim import 100 −0.36 0.27 91.1 100 −0.34 0.34 90.0
Image fusion 82.3 0.43 1.07 40.0 90 0.45 0.71 28.9
MD contourcontour / beam setup 96.2 0.36 0.88 85.5 98 1.21 0.89 44.9
Planning 82.3 3.44 2.34 41.5 64 5.81 1.76 3.12
MD plan review 34.0 3.22 2.16 86.7 24 4.19 1.97 75.0
MD plan approval 35.4 3.22 2.21 85.7 24 4.17 2.0 75.0
Patient‐specific QA 56 5.98 2.05 32.1
Physics chart review 64.6 3.90 2.31 86.3 60 6.11 1.63 50.0

Note: Staff compliance in recording QCL completion in the EMR, the average and standard deviation in the number of days post‐CT sim to complete the QCL, and on‐time performance in completing the QCL with respect to the ideal timeline are shown for 3D and IMRT treatments.

Abbreviations: 3D, three‐dimensional; EMR, electronic medical records; IMRT, intensity‐modulated radiotherapy; QCL, quality checklist, MD: Doctor of Medicine, QA: quality assurance.