Skip to main content
. 2022 Jul 27;23(9):e13725. doi: 10.1002/acm2.13725

TABLE 1.

Ablation study results for clinical target volume (CTV) segmentation on three‐dimensional (3‐D) magnetic resonance (MR) images against expert manual segmentation

Method Bladder localization CTV span detection CTV segmentation DSC p‐Value
1 2‐D Attention U‐Net 3‐D B2 U‐Net *0.81 ± 0.08 0.0274
2 3‐D U‐Net 3‐D B2 U‐Net *0.78 ± 0.05 1.81E − 08
3 3‐D U‐Net 2‐D Attention U‐Net 2‐D Attention U‐Net *0.80 ± 0.05 7.17E − 05
4 3‐D U‐Net 2‐D Attention U‐Net 3‐D Dense U‐Net *0.80 ± 0.10 0.0131
5 3‐D U‐Net 2‐D Attention U‐Net 3‐D U‐Net *0.81 ± 0.08 0.0265
6 3‐D U‐Net 2‐D Attention U‐Net 3‐D B2 Dense U‐Net *0.82 ± 0.05 0.0082
7 3‐D U‐Net 2‐D Attention U‐Net 3‐D B2 Attention U‐Net *0.80 ± 0.06 1.25E − 04
Proposed 3‐D U‐Net 2‐D Attention U‐Net 3‐D B2 U‐Net 0.85 ± 0.03

Note: The asterisk denotes statistical significance using the t‐test performed to compare the average DSC value reported from our proposed method against those of alternatives.

Abbreviations: 2‐D, two‐dimensional; 3‐D, three‐dimensional; DSC, Dice similarity coefficient.