Skip to main content
. 2022 Sep 30;12:419. doi: 10.1038/s41398-022-02190-8

Table 5.

Sensitivity and specificity in the recalibrated Extended model.

(a) Confusion matrix, threshold = 0.025
Threshold = 0.025 PPD No PPD
Predicted PPD: yes 6813 98,754
Predicted PPD: no 1968 353,922
(b) Sensitivity and specificity for different threshold values, within the combined dataset consisting of 461,457 women
Threshold Sens Spec PPV
0.005 0.844 0.597 0.039
0.025a 0.776 0.782 0.065
0.05 0.657 0.837 0.072
0.1 0.059 0.991 0.114
0.15 0.005 0.999 0.144

aMaximizes the sum of sensitivity and specificity.