Skip to main content
. 2022 Oct 4;12(43):28245–28253. doi: 10.1039/d2ra01679f

Method used to detect dopamine.

Method used Concentration range LOD Interference
FRET between acridine orange and CuO NPs32 1–40 μM 40 nM Ascorbic acid, uric acid, glucose, tryptophan and acetaminophen
A simple and convenient fluorescent strategy based on graphene quantum dots33 0.5–120 μM 0.16 μM NaCl, KCl, CaCl2, glucose, cysteine, ascorbic acid, epinephrine
Calorimetric detection using microfluidic paper34 0.5–4.75 μM 0.37 μM Ascorbic acid, uric acid
Calorimetric detection using gold nanoparticles35 0.5–10 μM 1.85 μM Amino acids, glucose, ascorbic acid, uric acid
FRET between PLGA-Cur-PDDA (our work) 0.01–0.2 mM 0.5–5 mM 22 nM 1.89 μM Tryptophan, adenine, uracil, guanine, cytosine, melamine, glutathione, cystine, kreatinine, tyrosine, silymarin, ascorbic acid, uric acid, l-tyrosine, tymarine, l-dopamine