Table 5.

Comparison of variances in HCC sensitivity and specificity across guidelines with EOB-MRI and CECT using Levene’s test

LESION TYPE SENSITIVITY SPECIFICITY
σ MR σ CT p -Value σ MR σ CT p -Value
 > 1 cm All Path HCC Reader #1 0.0140 0.053 0.037 0.044 0  < 10 –3
Reader #2 0.099 0.010 0.011 0.088 0 0.010
 > 1 cm imaging visible only Reader #1 0.216 0.151 0.347 0.088 0 0.010
Reader #2 0.148 0.033 0.015 0.207 0 0.010
All size All Path Reader #1 0.183 0.066 0.019 0.044 0  < 10 –3
Reader #2 0.115 0.023 0.011 0.088 0 0.010
All size imaging visible only Reader #1 0.258 0.167 0.179 0.088 0 0.010
Reader #2 0.169 0.062 0.018 0.207 0 0.010

σMR: EOB-MR standard deviation, σCT: CECT Standard deviation