Published in final edited form as: J Anal Toxicol. 2022 Feb 14;46(1):69–75. doi: 10.1093/jat/bkaa185

Table II.

ENDS Aerosol Metal Concentrations from Triplicate Measurements of Pod Devices, Including LODs and LSTDs (ng/10 Puffs)

Cr Ni Cu Zn Cd Sn Pb

LOD 0.125 0.250 0.200 5.00 0.050 0.100 0.050
LSTD 0.500 0.500 1.00 10.0 0.200 0.200 0.500
JUUL® Mint <0.500a <0.500–2.09 <1.00–16.0 <5.00–17.8 <0.050 <0.100–0.603 0.602–0.872
JUUL® Classic Tobacco <0.500a <0.500–2.87 <0.200–3.67 <10.0 <0.050 <0.100–0.438 <0.500
myblu™ Intense Mint-sation 0.626–0.727 30.1–108 146–174 <10.0 <0.050 81.2–127 <0.500–1.17
myblu™ Intense Tobacco Chill <0.500a 0.749–2.30 46.1–53.2 <10.0 <0.050 9.42–51.0 <0.500–2.88
Vuse Alto® Menthol 8.90–29.9 158–373 17.7–209 867–4,580 <0.050 9.88–44.1 96.5–463
Vuse Alto® Rich Tobacco <0.125–1.80 <0.500–97.9 <1.00–14.6 <10.0–40.5 <0.050 <0.100–0.290 0.908–16.3
a

Some results reported as <LSTD may also have replicates <LOD.