Skip to main content
. 2022 Sep 27;2022:3083647. doi: 10.1155/2022/3083647

Table 2.

Measurement results at different distances.

Measuring distance (m) Measured average value (mm) (average value of manual measurement = 199.8 mm) Correlation coefficient r between sensor and manual measurement results Mean absolute error (mm) Mean value of relative error (%)
0.5 198.9 0.987 2.7 1.34
0.7 196.7 0.949 5.9 2.89
0.9 189.5 0.982 10.3 5.25
1.0 183.8 0.977 16.0 8.35