EyeLink 1000+, EyeLink II, Tobii Pro Spectrum, SMI HiSpeed240, SMI RED250mobile |
Small head movements, chinrest, precision, filter on/off, oculomotor drift |
Holmqvist et al., (2021) |
Fove-0, Varjo VR-1, HTC Vive Pro Eye, EyeLink 1000, EOG |
Latency |
Stein et al., (2021) |
EyeLink 1000+, SMI RED250, SMI REDm, Tobii TX300, Tobii X2-60 |
Power spectral density, colour of noise, filter on/off, oculomotor drift |
Niehorster et al., (2021) |
EyeLink1000+, Tobii Pro Spectrum, FLEX |
Pupil-size artefact |
Hooge et al., (2021) |
SMI ETG2, SMI HTC Vive |
Accuracy, precision |
Pastel et al., (2021) |
Tobii Pro Spectrum, EyeLink 1000+ |
Microsaccades, precision |
Nyström et al., (2021) |
DPI Gen5.5, SMI HiSpeed 240, SMI HiSpeed 1250, SMI RED250mobile, SMI ETG 2, EyeLink II, EyeLink 1000+, Tobii X2-60, Tobii T120, Tobii TX300, Tobii Pro Spectrum |
Accuracy of movement amplitudes, measurement resolution, precision |
Holmqvist and Blignaut (2020) |
DPI Gen5.5, Tobii Pro Spectrum, EWET1 |
Accuracy, precision, pupil-size artefact, microsaccade detection, resolution |
Holmqvist et al., (2020) |
EyeLink 1000+, SMI RED250, SMI REDm, Tobii TX300, Tobii X2-60 |
Five different precision measures, filters on/off |
Niehorster et al., (2020c) |
SMI ETG2, Tobii Pro Glasses 2, PupilLabs |
Accuracy, precision, data loss |
Niehorster et al., (2020b) |
EyeLink 1000, Pupil Labs |
Accuracy, precision, drift, temporal precision, number of blinks, blink duration |
Ehinger et al., (2019) |
EyeLink 1000, SMI HiSpeed 1250 |
Vergence |
Hooge et al., (2019) |
EyeLink 1000, Stereotracker |
Accuracy, precision, main sequence |
Barsingerhorn et al., (2018) |
EyeLink 1000, EyeTribe |
Main sequence modelling, number of saccades |
Raynowska et al., (2018) |
SMI RED250, Tobii TX300 |
Fixation durations, number of fixations |
van Renswoude et al., (2018) |
EyeLink1000+, EyeTribe, SMI REDn, Tobii T60XL, Tobii TX300 |
Data loss and recovery during head movements |
Niehorster et al., (2018) |
DPI Gen 5.5, EyeLink1000, SMI HiSpeed 240, HiSpeed 1250, RED250, RED500 and REDm, Tobii TX300, T60 XL, X2-60, LC EyeFollower, EyeTribe |
Precision, power spectral density, colour of noise |
Wang et al., (2017) |
Tobii T60, Tobii T120, Tobii TX300 |
Saccadic reaction time |
Kenward et al., (2017) |
DPI Gen 6, Scleral Search Coil |
Precision, resolution, drift, noise colour |
Ko et al., (2016) |
EyeLink 1000, SMI ETG 2 |
Main sequence, saccade amplitudes |
Engbert et al., (2016) |
EyeTribe, Tobii EyeX, SeeingMachines faceLAB, SmartEye Pro, SmartEye Aurora |
Accuracy, precision, data loss |
Funke et al., (2016) |
EyeTribe, GazePoint GP3 |
Pupil diameter |
Coyne and Sibley (2016) |
EyeTribe, SMI RED250 |
Accuracy, data loss, fixation count |
Popelka et al., (2016) |
SMI RED250, EyeTribe |
Accuracy, temporal precision |
Ooms et al., (2015) |
DPI Gen 5.5, EyeLink1000, SMI HiSpeed 240, HiSpeed 1250, RED250, RED500 and REDm, Tobii TX300, T60 XL, X2-60, LC EyeFollower, EyeTribe |
Accuracy, precision, data loss |
Holmqvist (2015) |
EyeLink 1000, Scleral Search Coil |
Precision, microsaccades, oculomotor drift |
McCamy et al., (2015) |
LC Technologies EyeFollower, SMI RED250, SMI REDm, Tobii T120, TX300 and X2-60 |
Data loss and recovery during head movements |
Hessels et al., (2015) |
SMI RED250, SMI RED500, SMI HiSpeed1250, Tobii TX300 |
Accuracy, calibration |
Blignaut et al., (2014) |
EyeLink remote, SMI RED60 |
Number of fixations |
Wang et al., (2014) |
EyeLink 1000, EyeTribe |
Precision, drift |
Dalmaijer (2014) |
Tobii X120, T120, EyeLink 1000 |
Pupil foreshortening |
Brisson et al., (2013) |
EyeLink II and a piezoelectric sensor |
Microsaccade amplitudes |
McCamy et al., (2013) |
SMI RED250, Tobii TX300 |
Three precision measures, seating distance |
Blignaut and Beelders (2012) |
EyeLink 1000, Scleral Search Coil |
Accuracy, saccade dynamics, microsaccades, pupil-size artefact |
Kimmel et al., (2012) |
EyeLink 1000, Scleral Search Coil |
Pupil-size artefact |
Drewes et al., (2012) |
EyeLink II, Scleral Search Coil |
Saccade dynamics |
Lappe-Osthege et al., (2010) |
SMI RED50, SMI HED50 |
Accuracy, drift |
Komínková et al., (2008) |
Search Coil, Chronos Vision |
Accuracy, main sequence, torsion |
Houben et al., (2006) |
Tobii 1750, ASL, 501, ASL 504 |
Accuracy, data loss |
Nevalainen and Sajaniemi (2004) |
Tobii ET-17, LC EyeGaze |
Accuracy, data loss, drift |
Cheng and Vertegaal (2004) |
EyeLink I, Scleral Search Coil |
Saccade dynamics |
Frens and van der Geest (2002) |
DPI Gen 5, Scleral Search Coil |
Saccade dynamics |
Deubel and Bridgeman (1995) |