Skip to main content
. 2022 Oct;63(10):1611–1616. doi: 10.2967/jnumed.121.263102

TABLE 2.

Tissue Classification Based on Radiomic Feature Classes and Signatures in 4-Tissue Model

Classification accuracy Unharmonized Harmonized P
Median Range Median Range
Gray-level histogram
 Training 46.3 44.8–48.9 56.1 53.6–60.4 0.043
 Validation 45.8 42.5–49.2 53.8 46.3–56.3 0.043
Gray-level cooccurrence matrix
 Training 43.4 37.5–46.1 62.7 60.5–64.3 0.043
 Validation 39.2 36.7–41.7 57.5 50.8–65.0 0.042
Gray-level run-length matrix
 Training 46.3 43.4–47.1 63.0 57.3–64.5 0.042
 Validation 41.7 40.4–47.9 59.2 52.5–61.7 0.043
Gray-level size-zone matrix
 Training 43.4 41.4–43.8 86.0 83.0–87.5 0.043
 Validation 39.6 36.3–42.9 82.5 68.8–85.0 0.043
Neighborhood gray-tone difference matrix
 Training 42.1 39.6–45.0 62.7 60.0–64.3 0.043
 Validation 42.5 36.7–46.7 61.3 57.1–65.8 0.043
Radiomic signature
 Training 51.6 48.2–56.6 82.1 80.0–86.3 0.042
 Validation 48.8 42.9–50.8 81.3 67.5–82.9 0.043

Data are percentages.