Skip to main content
. 2022 Oct 6;12:16723. doi: 10.1038/s41598-022-21105-7

Table 1.

Mean and standard deviation (SD) for c (m/s), φ (rad) and Young’s modulus (kPa or Pa).

MRE AFM
c (m/s) φ (rad) EMRE (kPa) E (Pa)
Mask Mean ± SD Mean ± SD Mean ± SD Distance (µm) Mean ± SD
Ammon’s horn 4.4 ± 0.3 0.77 ± 0.11 50.8 ± 6.1 0 84 ± 40
Dentate Gyrus 3.2 ± 0.2 0.70 ± 0.13 27.7 ± 3.1 100 145 ± 82
1 pixel eroded 3.2 ± 0.2 0.68 ± 0.12 27.4 ± 3.2 200 177 ± 68
2 pixels eroded 3.2 ± 0.2 0.66 ± 0.12 26.8 ± 3.3 300 158 ± 80
3 pixels eroded 3.1 ± 0.2 0.65 ± 0.12 26.3 ± 3.3 400 142 ± 63

On the left, mean and SD of c (m/s) and φ (rad) and Young’s modulus (EMRE = 3 · |G*|) of the Ammon’s horn and DG masks and the DG masks reduced by 1 to 3 pixels from in vivo MRE, n = 10. On the right, mean and SD are given for distances from peak fluorescence intensity (in μm) from ex vivo AFM, 0 μm n = 15, 100 μm n = 15, 200 μm n = 15, 300 μm n = 10, 400 μm n = 5.