. 2022 Sep 13;60(11):3091–3112. doi: 10.1007/s11517-022-02648-3

Table 5.

Median values of EIGDR indices (R,RAandΔRA) computed over the six cliques considered for the PentaRay® catheter, median (Vb) and maximum (Vb-m) bipolar amplitude computed over the five innermost electrode pairs along the splines of the catheter, at different mapping points, taken at fibrotic (F) and non-fibrotic (NF) areas, respectively. Median and interquartile range (IQR) were also performed among F and NF points, separately

# Catheter site R RA ΔRA Vb(mV) Vb-m(mV)
F 1 3.42 4.79 1.04 0.04 0.60
2 6.18 6.18 1.00 0.90 4.46
3 2.45 4.75 1.95 1.65 3.61
4 3.25 8.03 2.18 0.10 2.31
5 1.47 5.35 3.03 1.46 1.63
6 2.33 6.46 4.22 1.35 1.42
7 2.22 2.24 1.02 0.16 0.30
8 2.42 9.52 4.30 0.39 1.53
9 2.18 7.24 4.17 1.31 3.06
10 2.19 8.05 4.31 1.30 1.43
11 3.40 9.92 3.06 0.25 0.50
12 1.77 16.2 9.83 1.91 3.52
13 1.56 2.56 1.57 1.01 2.00
14 2.60 13.4 3.94 0.44 0.51
15 0.91 2.27 1.83 0.84 3.73
16 1.05 1.29 1.38 0.45 1.20
17 1.18 4.90 4.57 1.46 1.89
18 6.07 6.31 1.00 0.06 0.09
19 1.80 3.70 3.00 0.37 5.04
median/IQR 2.22/1.47 6.18/4.08 3.00/2.78 0.84/1.05 1.63/2.66
NF 1 4.54 8.08 2.44 1.42 2.06
2 1.47 15.4 12.4 3.45 7.93
3 2.33 6.46 2.61 1.15 1.72
4 3.63 7.33 1.81 0.22 0.80
5 2.06 4.62 1.66 1.36 4.51
6 2.29 7.51 3.29 0.99 2.51
7 1.51 16.5 9.97 6.90 10.2
8 1.92 9.69 5.03 0.24 1.43
9 1.65 6.51 3.14 0.88 1.39
10 2.69 14.1 4.90 0.46 0.84
11 2.45 4.75 1.95 1.65 3.61
12 2.70 5.10 1.86 0.86 2.03
13 2.95 6.29 1.75 0.14 0.39
14 4.31 16.5 2.96 0.21 1.54
15 2.19 7.61 3.54 0.25 1.36
16 3.17 6.72 1.76 1.10 1.78
17 2.72 6.11 1.80 1.05 4.02
18 2.23 12.5 4.03 0.67 2.20
19 2.61 5.89 2.22 0.27 1.20
median/IQR 2.45/0.80 7.33/5.62 2.61/2.09 0.88/1.05 1.72/2.09
p-value* 0.17 0.03 0.26 0.35 0.32

* refers to the comparison of markers between F and NF areas