Skip to main content
. 2022 Sep 8;11:1018. [Version 1] doi: 10.12688/f1000research.125432.1

Table 1. MASCO-driven rhythms in wild type mice.

Strain Sex Age (wks) Activity recording MA dosage (%) Circadian period (h) References
DD LL
Baseline Dissociation MA treated MA post-treatment Baseline Dissociation MA treated MA post-treatment
1st comp 2nd comp 1st comp 2nd comp
C57BL/6J NA 12-16 Wheel 0.0075, 0.012, 0.0225 a 23.9 Yes NA 29 23.8 Coward et al., 2001 11
C57BL/6 ♂♀ 8-20 Wheel 0.005 → 0.01 23.64 No 24.04 → 24.17 23.74 Tataroglu et al., 2006 10
0.005 → 0.01 23.75 Yes 24.17 → 23.85 27.50 → 26.96 23.25
0.01 23.62 No 24.14 23.71
0.01 23.67 Yes 24.04 27.53 23.72
C57BL/6 0.005 AR (112-1976 lux) No 27.44
26.29 (112-1976 lux) No 28.21
C57BL/6 (SCNx) 0.005 AR No 26.29 AR or 23.54
C57BL/6J 12 Wheel 0.0025 NA Yes 24.0-24.4 26.2-36.7 23.4-23.7 Honma et al., 2008 13
C57BL/6J ♂♀ 13 Wheel 0.005 NA No 24.3 Pendergast et al., 2012 22
C57BL/6J ♂♀ 6-39 Wheel 0.005 23.63 No 24.23 25.32 (200-300 lux) No 29.25 Pendergast et al., 2013 18
C57BL/6J (SCNx) AR No 29.25, 30.58
C57BL/6J (PER2::LUC) NA 4-6 Wheel 0.005 23.67 No 24.67 Salaberry et al., 2017 28
C57BL/6J ♂♀ 9-17 IR 0.005 ∼24 Yes ∼24 ∼28 Ouk et al., 2016 31
25-33 ∼24 Yes ∼24 ∼35
49-56 ∼24 Yes ∼24 ∼35
C57BL/6J 10-15 Wheel 0.005 23.54 No 24.05 26.36 (350 lux) No 28.31 Mohawk et al., 2009 23
0.01 25.09 35.09
CBA x C57BL/6 ♂♀ 4.8 IR 0.005→0.01 23.7 No 24.2 → 47.3 Cuesta et al., 2012 29
Yes 24.3 → ? 28.5 → 47.3
7.5 0.005 23.7 No 23.9
Yes 24 ∼30
CBA x C57BL/6J ♂♀ 8 IR 0.005 NA Yes ∼24 ∼25.8 Ouk et al., 2018 30
BALB/c 6-19 Wheel 0.005 23.5 No 24.1 23.8 Masubuchi et al., 2001 12
23.3 Yes 23.5, 23.9 28.5-33.2 23.8
C3H (rd +/+) 8-20 Wheel 0.0025 → 0.0065 → 0.01 23.44 No 23.44 → 23.44 → 23.44 23.39 Tataroglu et al., 2006 10
 
∼23.61 Yes 23.50→ 23.50→ 23.50 29.50 → 29.00 → 26.83 23.56
 
 
∼23.30 No 23.47→ 23.53→ 23.70 ∼23.40
 
 
C3H (rd +/+) 0.005 AR (112-1976 lux) No 24.63
25.22 (112-1976 lux) No ∼24.94
C3H (rd +/+) (SCNx) ♂♀ 0.005 AR No 24.54

MA: Methamphetamine, DD: Constant darkness, LL: Constant light, AR: arrhythmic, NA: information is not available, IR: Infrared Sensor, SCN-X: SCN-lesioned, →: MA dose increased.

a

Amphetamine.