Table 5.

Maximum flexion delay (s) between assistive pattern and equivalent leg

Pattern Echo
Variable gait speed − 0.023 ± 0.071 (0.074) − 0.015 ± 0.063 (0.065)
Constant gait speed − 0.017 ± 0.037 (0.041) − 0.007 ± 0.034 (0.035)
Global − 0.021 ± 0.060 (0.064) − 0.012 ± 0.053 (0.055)

Mean ± standard deviation (RMS error between brackets)