Abstract
Resting heart rate (RHR) is a potential cardiac disease prevention target because it is strongly associated with cardiac morbidity and mortality, yet community-based monitoring of RHR remains in its infancy. Recently, smartwatches have become available enabling measurement with non-intrusive devices of relationships between RHR and other factors outside the laboratory. We carried out cross-sectional observational retrospective analysis of anonymised smartwatch data obtained by participants in their everyday lives between 2016 and 2021 in a single centre community-based study, using convenience sampling. Between participants, overall RHR means strongly or moderately inversely correlated with means of stand hour (SH), calculated VO2 max, walking and running distance (WRD), steps and flights climbed (FC). Within participants, in quarterly averages, RHR inversely correlated moderately with frequency of standing (stand hours, SH). RHR also inversely correlated moderately with heart rate variability (HRV), consistent with the known impact of increasing parasympathetic dominance on RHR. These within participant correlations suggest that RHR might be modifiable by changes in SH and HRV within individuals. Indeed, analysing paired daily data, relationships between these three categories were dose dependent. 15 SH versus 5 SH associated with a reduction of 10 beats per minute in mean RHR and increase in mean HRV of 14 ms, respectively. We conclude that within individuals, RHR inversely correlates with frequency of standing and HRV, with paired daily measurements indicating effects are mediated that day. RHR also inversely correlates with fitness and activity measures between participants. Our findings provide initial community-based observational evidence supporting further prospective interventional investigation of frequency of standing or HRV modifiers, alongside more familiar interventions, for cardiac disease prevention.
Keywords: Cardiovascular disease, diabetes, digital health, general, exercise, lifestyle, wearables, personalised medicine
Introduction
Numerous lab-based studies have evidenced that higher resting heart rate (RHR) is associated with cardiovascular disease morbidity and mortality1–5 but there has been relatively little work done to establish factors influencing RHR in the community. Smartwatches and smart phones are new technologies collecting large longitudinal datasets on VO2 max, steps, posture, elevation (measured as flights climbed, FC), walking and running distance (WRD) and heart rate variability (HRV), in the community.6 Here, we exploit this data-gathering to investigate for the first time in retrospective observational study, which of these factors correlate with RHR in free-living humans on a day-to-day basis and over quarterly time periods.
Higher RHR is an indicator of increased CVD mortality in apparently healthy individuals and in patients with coronary heart disease (CHD), independently of other major risk factors.2,7 RHR is controlled by autonomic nervous system poise (ANS), which can in turn be modulated by many kinds of stress. Increased sympathetic system dominance during stress, which will raise RHR, can itself be measured non-invasively by a decrease in HRV.8 HRV is inversely associated with CVD risk.9 Previous meta-analysis found that an increase of 1 ms in lab-measured HRV (standard deviation of NN intervals, SDNN) reduces risk of CVD by ∼1%.9 An acute decrease in HRV accompanies the shift from parasympathetic to sympathetic dominance during the transition from horizontal to more upright body positions10,11; in contrast however, chronic standing has been associated previously with elevated HRV.12 Some watches measure frequency of standing throughout the day, termed the Stand Hour (SH), defined as standing with movement for 1 minute in an hour, arguably more akin to a desk break; however, the significance of this measure on HRV and RHR is unknown. In previous work, psychological benefits of desk breaks have been identified13 and it is known that physical activity can reduce higher risk of death associated with long sitting time14; however, physiological mechanisms remain largely unknown. Further investigation of SH might therefore provide a means to establish a better evidence base for prospective studies investigating desk break interventions.
Cardiorespiratory fitness (VO2 max) also inversely correlates with RHR at a population level1; however, previous studies have tended to focus on effects of types of activities on RHR rather than how overall activity (measured by WRD, FC, steps) impacts RHR, and how strongly. The purpose of the current study was to determine whether changes in activity, fitness and/or SH correlate with changes in RHR and HRV in the community, within and between participants.
Methods
Ethical approval, recruitment, exclusion criteria and data collection
The present study was approved by the University of Dundee School of Medicine Research Ethics Committee (SMED REC Number 20/55). Recruitment of 20 healthy volunteers took place in early 2021. Convenience sampling occurred via social media, word of mouth and email distribution. The sample size was also based on convenience, determined by the time available for the project. Although we were powered to answer the questions we posed for ourselves, more participants would have given more power to stratify the cohort by age, BMI and other factors that might contribute towards the correlations we observed. Recruitment aimed to be balanced in terms of both age and gender, targeting mainly staff and students at the University of Dundee, as well as the Dundee Roadrunners, a local amateur running club. All eligible volunteers who submitted any data to us had it analysed and included in this study. Volunteers had to give written consent and were able to withdraw from the research project at any stage. No consented eligible participants who provided data did withdraw. Exclusion criteria for this study were individuals: (1) outside the age range of 18–60 years, (2) currently taking any prescribed medication or receiving treatment from a medical doctor or (3) currently living outside the Tayside or Fife Health Board areas. In addition, there were technical requirements that would exclude, if the prospective participant was (4) not regularly wearing a watch measuring the categories listed, or (5) with Apple iPhone software not as up to date as iOS 14 or (6) without any of the data categories syncing to the Apple Health application. Watch data was extracted using a third-party app “Health Auto Export to CSV”, which converted the data into a conventional CSV file. Participants were reimbursed for the cost of the app. The CSV file was uploaded by the participant directly to University of Dundee OneDrive secure server in a pre-anonymised manner. Volunteers were asked to export data extending from when they first started regularly wearing their watch until present so that as much data as possible could be analysed. All the analysed data was captured between 2016 and early 2021. The analysed and published data were fully anonymised. Data was not collected for every category from every device. Certain categories, including SH, VO2 max and HRV, are either unique to Apple devices, or they are only captured by the phone app if they are collected on an Apple watch. For correlations, we could not include data from an individual if their device had only captured one of the data categories under investigation. We also excluded data values of 0 and for histograms restricted the ranges where there was insufficient data but other than this, all data were included for analysis, both strategies recommended recently by others.15 Except in sub-group analysis, each pairwise correlation includes data collected from at least ten participants, as indicated in the tables. A STROBE checklist was followed when planning the manuscript. As far as possible we followed recently published guidelines on research involving wearables.15
Measurements
Step count (SC) and stand hour (SH)
Apple watches have been validated previously for SC against manual assessment of steps in a short video recording16 and against a reference standard pedometer.17 Other studies have validated that other brands of consumer step counter including Garmin perform similarly to an Apple device.18,19 Another study validated a Garmin watch against a research-grade pendulum pedometer (Yamax) (Mean Absolute Percentage of Error [MAPE]-4).20 SH, a measurement on Apple watches only, represents the number of hours where an individual has stood and moved for at least 1 minute. Apple's method of detection for this is not in the public domain but thought to be similar to SC using an accelerometer and gyroscope. To develop an idea of how this related to movement in the community setting, we analysed a 1-month sample of hourly data from one watch. We found that 93% of SH were recorded in an hour where at least one step was recorded and in addition, SH were recorded more often when more steps were recorded. One SH was recorded as follows: No steps in 1 hour, SH recorded 8% of the time n = 251; 1–10 steps in 1 hour, SH recorded 22% of the time n = 9; 11–50 steps in one hour, SH recorded 62% of the time n = 81; 51–100 steps in one hour, SH recorded 95% of the time n = 87; 101–250 steps in one hour, SH recorded 97% of the time n = 138 and over 251 steps in one hour, SH recorded 100% of the time n = 177.
Walking and running distance (WRD)
WRD is an estimate of the number of kilometres travelled when walking or running. The watches assess this parameter with the use of global positioning satellite (GPS) communication, which detects their location.21 Studies of Apple and Garmin watches have found that they are accurate in recording distances travelled, when compared to trundle wheel reference measurements (MAPE average 2.8)21 and in an accurately measured public half marathon.22
Resting heart rate
Apple watch RHR measurements have previously been validated against manual RHR measurements (MAPE 0.07),23 an ECG (Concordance Correlation Coefficient (CCC) > 0.9).24 Garmin watch heart rate measurement has been validated by correlation with a Polar RS400 chest strap monitor (r = 0.997 p < 0.0001)25 and gold-standard chest strap (gold standard because it corresponds so closely with ECG data).26
Heart rate variability (HRV)
Measurements from only Apple watches were taken in this study because only these devices record this information in the Health app. Apple watches have been validated against the Polar H7 (CCC 0.989 and 0.977, respectively) in measuring HRV.27 The Apple HRV algorithm evaluates the SDNN (standard deviation of the NN interval) HRV measure, which is most sensitive to ultralow and low frequency fluctuations in heart rate,28 whereas the ANS system impacts both low frequency and high frequency heart rates.29 When measured over 24 hours, SDNN has been inversely correlated with CVD mortality30 but instead of measuring over 24 hours, the Apple Health app reports measurements at one or more discrete time points during the day, which we then derived a mean daily value from.
Flights climbed (FC)
FC is simply the number of times 10 feet or 3 metres of elevation gain, when walking, running or climbing, is detected by a watch. Apple and Garmin watches measure this using built-in barometric altimeters that detect atmospheric pressure changes in line with their accelerometers and gyroscopes.31
VO2 max
Also known as maximal oxygen uptake, VO2 max is the maximal oxygen that a person can utilise during intense exercise. It is viewed as a marker of overall physiological fitness. Repeated longitudinal measurement of VO2 max by cardiopulmonary exercise testing (CPET) is impractical to conduct during community-based exercise, which occurs at a variety of intensities.32 Calculated VO2 max on Apple watches has been validated against CPET in a technical note published on the Apple website. It is unclear if there has been peer review of this data.
For RHR, HRV and VO2 max, if more than one value was recorded for a given day, these values were averaged before analysis.
Statistical analysis
Statistical testing was conducted using the “Statistical Package for the Social Sciences” (SPSS) software, GraphPad Prism, MS Excel and for repeated measures correlation, we used rmcorrShiny.33,34 With the exception of VO2 max, all daily data were not normal distribution (data not shown), and scatter plots were suggestive of heteroscedasticity for most daily data categories, with curvilinear correlations. We used Pearson's correlation for any data which involved averaging of data over time or between individuals as this resulted in scatter plots with clear linear relationships between variables. The following cut-off values were used to interpret correlations: r < 0.20 = very weak; 0.20 to 0.39 = weak; 0.40 to 0.59 = moderate; 0.60 to 0.79 = strong; and 0.80 to 1.0 = very strong.35 Error bars on histograms are SEM.
Data availability statement
Anonymised data supporting the findings of this study may be made available on reasonable request from the corresponding author GR, and where this is consistent with the terms of the ethical approval.
Results and discussion
Cohort description
In this study we recruited twenty healthy male and female participants aged 18–60 to study their smartwatch data. The population is described in Table 1. 70% of the cohort was below 30 years old, 60% had a BMI < 25 and 60% were male. All but one of the cohort was not currently smoking. Mean values of measurements we analysed are shown for the whole cohort in Table 2.
Table 1.
Demographic characteristics of the whole cohort.
| Gender | Male | Female | |
|---|---|---|---|
| (n) | 12 | 8 | |
| (%) | 60% | 40% | |
| BMI | <24.99 | >25 | |
| (n) | 12 | 8 | |
| (%) | 60% | 40% | |
| Smoking | Never | No | Yes |
| (n) | 11 | 8 | 1 |
| (%) | 55% | 40% | 5% |
| Age | 18–29 | 40–49 | 50–60 |
| (n) | 14 | 5 | 1 |
| (%) | 70% | 25% | 5% |
Table 2.
Mean values for the whole cohort.
| Mean activity measures/day | |
|---|---|
| Steps | 8600.8 |
| Walking/running distance (WRD, km) | 7.2 |
| Flights climbed (FC) | 15.8 |
| Cardiorespiratory fitness | |
| VO2 max (ml/kg/min) | 41.0 |
| Heart measurements | |
| Heart rate variability (HRV, ms) | 49.6 |
| Resting heart rate (RHR, bpm) | 59.1 |
Correlations between RHR and other smartwatch measurements within participants and between participants
We followed guidance on analysis of repeated measures data in a series of short notes by Bland and Altman,36–38 to distinguish ‘within participant’ from ‘between participant’ correlations.
Between participant correlations
To determine whether a low RHR correlated with any of the other parameters between participants, we carried out correlations of participant means.37 We found that RHR inversely correlated moderately or strongly with HRV, SH, VO2 max, Steps, WRD and FC (Table 3). VO2 max and WRD also both correlated strongly with HRV (Table 3).
Table 3.
Pearson correlations of participant means.
| Pairwise correlations | Correlation coefficient (r) | p-Value | Participants (n) | |
|---|---|---|---|---|
| Data category 1 | Data category 2 | |||
| Resting heart rate | Stand hours | −0.689 | 0.028 | 10 |
| Resting heart rate | Heart rate variability | −0.530 | 0.051 | 14 |
| Resting heart rate | VO2 max | −0.685 | 0.010 | 13 |
| Resting heart rate | Walking and running distance | −0.594 | 0.020 | 15 |
| Resting heart rate | Flights climbed | −0.573 | 0.016 | 17 |
| Resting heart rate | Step count | −0.489 | 0.047 | 17 |
| Stand hours | Heart rate variability | 0.287 | 0.393 | 11 |
| VO2 max | Heart rate variability | 0.678 | 0.008 | 14 |
| Walking and running distance | Heart rate variability | 0.638 | 0.019 | 13 |
| Flights climbed | Heart rate variability | 0.286 | 0.302 | 15 |
| Step count | Heart rate variability | 0.491 | 0.063 | 15 |
Within participant correlations
When searching for new public health interventions targeting RHR, ideally there would be evidence that changing a variable within a participant, is associated with a change in RHR within that participant. To investigate this, we next performed a repeated measures correlation within participants.33,36
In scatter plots we found that relationships in daily data were curvilinear but that relationships became linear in quarterly paired data. We derived quarterly mean values for RHR, SH, HRV, steps, WRD, FC and VO2 max for each individual participant and determined correlations for these data within participants. As in the ‘between participants’ analysis, SH inversely correlated moderately with RHR in the ‘within participants’ analysis (Table 4, Figure 1(a)) and HRV also inversely correlated moderately with RHR (Table 4, Figure 1(b)). One likely mechanism for these correlations is increasing dominance of the parasympathetic system in response to increasing SH. Consistent with this possibility, SH correlated moderately with HRV (Table 4, Figure 1(c)). To test for possible impact of age, sex or BMI, we examined three sub-groups: (a) individuals aged 18–30; (b) males and (c) individuals with BMI < 25. We found that correlation of SH with HRV was maintained in all three sub-groups. Inverse correlation of SH with RHR, as well as HRV with RHR, was also maintained in the first two sub-groups but ablated in individuals with BMI < 25 (Table 4). Although SH/HRV correlation was observed in all groups, these results suggest that SH may be more effective at lowering RHR in overweight people. It is well known that obesity increases dominance of the sympathetic system39,40 and it can be speculated that this defect is corrected by increasing SH. VO2 max also correlated weakly with HRV but did not correlate with RHR.
Table 4.
Repeated measures correlation coefficient, within participants.
| Pairwise correlations | Repeated measures correlation coefficient rrm | p-Value | Participants n | ||||
|---|---|---|---|---|---|---|---|
| Data category 1 | Data category 2 | Young only rrm (n; p-value) | Male only rrm (n; p-value) | BMI < 25 only rrm (n; p-value) | |||
| Resting heart rate | Stand hours | −0.434 | 0.000 | 10 | −0.442 (9; 0.001) | −0.438 (7; 0.002) | −0.028 (7; 0.878) |
| Resting heart rate | Heart rate variability | −0.439 | 0.000 | 14 | −0.460 (11; 0.000) | −0.462 (10; 0.000) | −0.050 (10; 0.720) |
| Resting heart rate | VO2 max | −0.009 | 0.954 | 13 | |||
| Resting heart rate | Walking and running distance | −0.009 | 0.941 | 15 | |||
| Resting heart rate | Flights climbed | −0.05 | 0.646 | 17 | |||
| Resting heart rate | Step count | −0.003 | 0.979 | 17 | |||
| Stand hours | Heart rate variability | 0.542 | 0.000 | 11 | 0.567 (10; 0.000) | 0.591 (7; 0.000) | 0.503 (7; 0.003) |
| VO2 max | Heart rate variability | 0.215 | 0.103 | 14 | |||
| Walking and running distance | Heart rate variability | 0.051 | 0.66 | 13 | |||
| Flights climbed | Heart rate variability | −0.083 | 0.444 | 15 | |||
| Step count | Heart rate variability | −0.032 | 0.764 | 15 | |||
Figure 1.
Within individuals repeated measures correlations. Repeated measures correlations were carried out using RMCorrShiny on quarterly averaged data for (a) SH vs. RHR, (b) RHR vs. HRV and (c) HRV vs. SH.
Investigation of relationships between daily RHR, daily SH and daily HRV
We investigated whether differences in daily HRV and SH associated with differences in RHR in daily paired measurements. Plotting histograms, we discovered that between 2 and 17 SH, RHR was lower on days with higher SH, in a dose dependent manner (Figure 2(a)). A similar dose dependent effect was observed between HRV and RHR (Figure 2(b)). The relationship between SH and RHR is likely mediated by HRV, as HRV was higher when SH was higher (SH 5, HRV 40 ± 4 ms; SH 15, HRV 54 ± 4 ms, p = 0.03). These findings may be physiologically meaningful. On days with 15 SH, mean RHR was 10 beats per minute lower than on days with 5 SH (Figure 2(a)). Taken together with previous meta-analysis findings that an increase of 1 ms in lab-measured HRV (standard deviation of NN intervals, SDNN) reduces risk of CVD by ∼1%,9 the correlations we observe might suggest that promotion of desk breaks or other approaches such as standing desks, aimed at increasing frequency of standing throughout the day, merit prospective investigation for CVD prevention.
Figure 2.
Histograms describing relationships between Standing Hours, Heart Rate Variability and Resting Heart Rate-daily values. Pairwise histograms are exhibited between (a) Resting Heart Rate and Stand Hours and (b) Heart Rate Variability and Resting Heart Rate. Pairwise statistical testing of selected higher and lower values in each histogram determined that the differences observed were significant (* is p < 0.05; ** is p < 0.01 and *** is p < 0.001).
Strengths and limitations of our study
The wearable devices that were used were participants’ own devices and were mostly Garmin and Apple watches, with one Polar watch. 15/20 of the wearables were Apple watches and two-thirds of the pair-wise analyses, including each one involving SH, HRV or VO2 max, do not contain any Garmin data. The data extraction strategy depended on the participant using an iPhone with iOS14 installed, so although the watch technology for data acquisition varied, the data storage platform was the same for each participant. Data recorded by the phone itself for categories including steps, WRD, FC and SH, will be present. Use of two devices to record activity will however have minimised periods of time when activity was not being monitored by any device, which is likely to have been of benefit, as we did not identify a satisfactory way to define and therefore adjust for non-wear time. We also collected demographic data as recommended.15
Regarding known limitations, our study could not be as well controlled as a lab-based one could have been; however, a key strength of our study utilising wearables is its ethnographic, in-community measurements outside an artificial lab environment that might itself act as a stressor affecting ANS poise (often referred to as the ‘white-coat’ effect15). In addition, the amounts of the daily data are far greater than generally can be achieved in a lab study, as also recognised previously.15 Our observational data does not demonstrate causality. As we studied only healthy, active individuals, based on convenience sampling, external validity, particularly for ‘at-risk’ patient groups has not been established and will need to be investigated in follow-up studies.
Conclusion
By analysing high volume smartwatch data, our study finds that in the community, overall fitness and activity inversely correlates with RHR between participants. Frequency of standing (SH) and HRV both inversely correlate with RHR not only between participants but also within participants, suggesting they may particularly give individuals agency to modify their RHR. Our investigation provides community-based observational evidence supporting further prospective investigation of SH, in addition to more familiar interventions based on fitness and activity, as a potential CVD prevention strategy, through activities such as promotion of desk breaks. We recognise that observations made in existing watch owners will not necessarily translate to the patient groups who might benefit most from cardiac disease prevention interventions. The external validity for at-risk groups of these initial observations, should now therefore be tested through additional observational and interventional studies.
Acknowledgements
Dr Jane Davidson processed participant expenses claims during COVID-19 restrictions. Dr Alison McNeilly helped with recruitment and her and Dr Colin Murdoch, Dr Andrew Murphy and Prof Mike Ashford provided helpful comments on the manuscript or project. GR acknowledges funding from BHF, Diabetes UK and The Academy of Medical Sciences. MS is supported by a MRC studentship.
Footnotes
Author contributions: JA and MS recruited participants. JA, MS and GR were each involved in data analysis. GR wrote the original draft of the manuscript, partly based on an earlier dissertation by JA. All three authors then collaborated on improving the manuscript.
The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
Funding: The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: Work of this team is supported by British Heart Foundation, Academy of Medical Sciences, Diabetes UK and MRC.
Ethical approval: This was obtained as described in the Methods.
Guarantor: GR.
ORCID iDs: Magdalena Sovakova https://orcid.org/0000-0002-1481-2427
Graham Rena https://orcid.org/0000-0002-9121-1350
References
- 1.Saxena A, Minton D, Lee D-c, et al. Protective role of resting heart rate on all-cause and cardiovascular disease mortality. Mayo Clin Proc 2013; 88: 1420–1426. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Kolloch R, Legler UF, Champion A, et al. Impact of resting heart rate on outcomes in hypertensive patients with coronary artery disease: findings from the INternational VErapamil-SR/trandolapril STudy (INVEST). Eur Heart J 2008; 29: 1327–1334. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Cook S, Togni M, Schaub MCet al. et al. High heart rate: a cardiovascular risk factor? Eur Heart J 2006; 27: 2387–2393. [DOI] [PubMed] [Google Scholar]
- 4.Jouven X, Zureik M, Desnos Met al. et al. Resting heart rate as a predictive risk factor for sudden death in middle-aged men. Cardiovasc Res 2001; 50: 373–378. [DOI] [PubMed] [Google Scholar]
- 5.Benetos A, Rudnichi A, Thomas Fet al. et al. Influence of heart rate on mortality in a French population: role of age, gender, and blood pressure. Hypertension 1999; 33: 44–52. [DOI] [PubMed] [Google Scholar]
- 6.Bayoumy K, Gaber M, Elshafeey A, et al. Smart wearable devices in cardiovascular care: where we are and how to move forward. Nat Rev Cardiol 2021; 18: 581.–. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Kristal-Boneh E, Silber H, Harari Get al. et al. The association of resting heart rate with cardiovascular, cancer and all-cause mortality. Eight year follow-up of 3527 male Israeli employees (the CORDIS study). Eur Heart J 2000; 21: 116–124. [DOI] [PubMed] [Google Scholar]
- 8.Hjortskov N, Rissén D, Blangsted AKet al. et al. The effect of mental stress on heart rate variability and blood pressure during computer work. Eur J Appl Physiol 2004; 92: 84–89. [DOI] [PubMed] [Google Scholar]
- 9.Hillebrand S, Gast KB, de Mutsert R, et al. Heart rate variability and first cardiovascular event in populations without known cardiovascular disease: meta-analysis and dose–response meta-regression. EP Europace 2013; 15: 742–749. [DOI] [PubMed] [Google Scholar]
- 10.Pomeranz B, Macaulay RJ, Caudill MA, et al. Assessment of autonomic function in humans by heart rate spectral analysis. Am J Physiol 1985; 248(Pt 2): H151–H153. [DOI] [PubMed] [Google Scholar]
- 11.Watanabe N, Reece J, Polus BI. Effects of body position on autonomic regulation of cardiovascular function in young, healthy adults. Chiropr Osteopat 2007; 15: 19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Hallman DM, Krause N, Jensen MTet al. et al. Objectively measured sitting and standing in workers: cross-sectional relationship with autonomic cardiac modulation. Int J Environ Res Public Health 2019; 16: 650. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Jennifer KC, Esther M, Ingrid JMHet al. et al. Physical activity and relaxation during and after work are independently associated with the need for recovery. J Phys Act Health 2015; 12: 109–115. [DOI] [PubMed] [Google Scholar]
- 14.Ekelund U, Steene-Johannessen J, Brown WJ, et al. Does physical activity attenuate, or even eliminate, the detrimental association of sitting time with mortality? A harmonised meta-analysis of data from more than 1 million men and women. The Lancet 2016; 388: 1302–1310. [DOI] [PubMed] [Google Scholar]
- 15.Nelson BW, Low CA, Jacobson Net al. et al. Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research. npj Digit Med 2020; 3: 90. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Veerabhadrappa P, Moran MD, Renninger MDet al. et al. Tracking steps on apple watch at different walking speeds. J Gen Intern Med 2018; 33: 795–796. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Breteler MJ, Janssen JH, Spiering Wet al. et al. Measuring free-living physical activity with three commercially available activity monitors for telemonitoring purposes: validation study. JMIR Form Res 2019; 3: e11489. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Wen D, Zhang X, Liu Xet al. et al. Evaluating the consistency of current mainstream wearable devices in health monitoring: a comparison under free-living conditions. J Med Internet Res 2017; 19: e68. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Svarre FR, Jensen MM, Nielsen Jet al. et al. The validity of activity trackers is affected by walking speed: the criterion validity of Garmin Vivosmart(®) HR and StepWatch(™) 3 for measuring steps at various walking speeds under controlled conditions. PeerJ 2020; 8: e9381–e. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Simunek A, Dygryn J, Gaba Aet al. et al. Validity of Garmin Vivofit and polar loop for measuring daily step counts in free-living conditions in adults. Acta Gymnica 2016; 46: 129–135. [Google Scholar]
- 21.Gilgen-Ammann R, Schweizer T, Wyss T. Accuracy of distance recordings in eight positioning-enabled sport watches: instrument validation study. JMIR Mhealth Uhealth 2020; 8: e17118. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Pobiruchin M, Suleder J, Zowalla Ret al. et al. Accuracy and adoption of wearable technology used by active citizens: a marathon event field study. JMIR Mhealth Uhealth 2017; 5: e24. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Xie J, Wen D, Liang Let al. et al. Evaluating the validity of current mainstream wearable devices in fitness tracking under various physical activities: comparative study. JMIR Mhealth Uhealth 2018; 6: e94. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Thomson EA, Nuss K, Comstock A, et al. Heart rate measures from the Apple Watch, fitbit charge HR 2, and electrocardiogram across different exercise intensities. J Sports Sci 2019; 37: 1411–1419. [DOI] [PubMed] [Google Scholar]
- 25.Engström E, Ottosson E, Wohlfart Bet al. et al. Comparison of heart rate measured by polar RS400 and ECG, validity and repeatability. Adv Physiother 2012; 14: 115–122. [Google Scholar]
- 26.Pasadyn SR, Soudan M, Gillinov M, et al. Accuracy of commercially available heart rate monitors in athletes: a prospective study. Cardiovasc Diagn Ther 2019; 9: 379–385. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Hernando D, Roca S, Sancho Jet al. et al. Validation of the apple watch for heart rate variability measurements during relax and mental stress in healthy subjects. Sensors (Basel) 2018; 18: 2619. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Umetani K, Singer DH, McCraty Ret al. et al. Twenty-four hour time domain heart rate variability and heart rate: relations to age and gender over nine decades. J Am Coll Cardiol 1998; 31: 593–601. [DOI] [PubMed] [Google Scholar]
- 29.Shaffer F, Ginsberg JP. An overview of heart rate variability metrics and norms. Front Public Health 2017; 5: 258. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation 1996; 93: 1043–1065. [PubMed] [Google Scholar]
- 31.Henriksen A, Haugen Mikalsen M, Woldaregay AZ, et al. Using fitness trackers and smartwatches to measure physical activity in research: analysis of consumer wrist-worn wearables. J Med Internet Res 2018; 20: e110. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Smirmaul B, Bertucci D, Teixeira I. Is the VO2max that we measure really maximal? Front Physiol 2013; 4: 203. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Bakdash JZ, Marusich LR. Repeated measures correlation. Front Psychol 2017; 8: 456. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Marusich LR, Bakdash JZ. Rmcorrshiny: a web and standalone application for repeated measures correlation. F1000 Res 2021; 10: 697. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Schober P, Boer C, Schwarte LA. Correlation coefficients: appropriate use and interpretation. Anesth Analg 2018; 126: 1763–1768. [DOI] [PubMed] [Google Scholar]
- 36.Bland JM, Altman DG. Calculating correlation coefficients with repeated observations: part 1—correlation within subjects. Br Med J 1995; 310: 446. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Bland JM, Altman DG. Calculating correlation coefficients with repeated observations: part 2—correlation between subjects. Br Med J 1995; 310: 633. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Bland JM, Altman DG. Statistics notes: correlation, regression, and repeated data. Br Med J 1994; 308: 896. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Smith MM, Minson CT. Obesity and adipokines: effects on sympathetic overactivity. J Physiol 2012; 590: 1787–1801. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Manolis AJ, Poulimenos LE, Kallistratos MSet al. et al. Sympathetic overactivity in hypertension and cardiovascular disease. Curr Vasc Pharmacol 2014; 12: 4–15. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Anonymised data supporting the findings of this study may be made available on reasonable request from the corresponding author GR, and where this is consistent with the terms of the ethical approval.


