Skip to main content
. 2022 Oct 10;18(10):e1010541. doi: 10.1371/journal.pcbi.1010541

Table 3. Details on meshes used in mesh resolution study.

Average edge length (mean ± SD across patients, microns) Number of elements (mean ± SD across patients, millions of elements)
Very low 1029 ± 1.6 1.15 ± 0.28
Low 630 ± 0.1 5.57 ±1.35
Medium 426 ± 0.5 16.7 ± 4.1
High 275 ± 0.02 69.1 ± 16.9