Comparison of the averaged values of DNA purity and concentration yielded by different DNA extraction methods and estimated execution time for each method

Method Onychomycosis models DNA purity (Mean ± SE) DNA concentration (Mean ± SE) μg/ml Time estimation
Extraction Purification
Method 1
Steel bullet + lysis buffer Phenol chloroform Model 1 1.91 ± 0.10 244 ± 31.27 ≃80 min
Model 2 1.84 ± 0.52 490 ± 54.82
Method 2
Freezing + steel bullet+ lysis buffer Phenol chloroform Model 1 1.74 ± 0.01 366 ± 49.69 ≃140 min
Model 2 1.93 ± 0.04 884 ± 83.56
Method 3
Steel bullet Commercial kit Model 1 1.77 ± 0.09 169.2 ± 27.94 ≃65 min
Model 2 1.3 ± 0.18 440 ± 50.82
Control method
Glass beads + lysis buffer Phenol chloroform Model 1 1.86 ± 0.12 117 ± 32.48 ≃80 min
Model 2 1.83 ± 0.05 262 ± 39.75