Skip to main content
. 2022 Oct 10;12:16998. doi: 10.1038/s41598-022-21276-3

Table 2.

Univariable logistic regression analysis of predictors for poor outcome.

OR (95% CI) P value
Age 1.031 (0.980, 1.083) 0.239
Initial NIHSS 1.137 (0.999, 1.293) 0.051
Baseline ASPECTS 1.009 (0.724, 1.406) 0.958
Intravenous thrombolysis 1.017 (0.363, 2.849) 0.974
the procedure time 1.004 (0.999, 1.008) 0.131
Passes of retriever 1.510 (0.726, 3.141) 0.270
mTICI 2b-3 0.518 (0.190, 1.412) 0.198
CE-ASPECTS 0.813 (0.684, 0.966) 0.019
CE locations
C 4.333 (0.854, 21.986) 0.077
M1 2.359 (0.844, 6.597) 0.102
M2 2.956 (1.052, 8.307) 0.040
M4 4.600 (1.432, 14.778) 0.010
M5 2.956 (1.052, 8.307) 0.040
M6 3.667 (1.203, 11.174) 0.022
CE volume (5 ml) 1.283 (1.045, 1.576) 0.017

NIHSS National Institutes of Health Stroke Scale, CE contrast enhancement, ASPECTS Alberta stroke program early computed tomography score, C caudate nucleus, mTICI modified Thrombolysis in Cerebral Infarction, 95% CI indicates 95% confidence interval, OR odds ratio.