Skip to main content
. 2022 Sep 28;13:977372. doi: 10.3389/fphar.2022.977372

TABLE 4.

Mean values and precision and bias errors of gentamicin minimal PBPK model developed.

Preterm Term
C 2 h (mg/L) C 24 h (mg/L) CL (L/h) C 2 h (mg/L) C 24 h (mg/L) CL (L/h)
Mean value observed 17.7 2.92 0.09 13.8 1.41 0.19
Mean value predicted 17.4 2.62 0.11 15.4 0.89 0.23
Mpe (%) 8.08 −5.04 26.5 16.3 −28.8 27.7
Afe 1.02 0.92 1.24 1.14 0.68 1.26
Aafe 1.22 1.23 1.26 1.20 1.47 1.29

C, concentration; CL, clearance; MPE, mean prediction error; AFE, average-fold error; AAFE, absolute average-fold error.