Skip to main content
. 2022 Feb 18;75(8):1379–1388. doi: 10.1093/cid/ciac152

Table 2.

Measured Acetaminophen Concentrations by Arm

Treatment Arm
Acetaminophen
(ng/mL)
Control
(ng/mL)
Time, hours
0 1601 (124–6660) 5122 (379–11051)
6 4235 (2706–5788) 2399 (693–5401)
12 4824 (3263–6807) 750 (188–3036)
18 4434 (2996–6507) 436 (118–1107)
24 4461 (3515–6362) 107 (0–430)
30 4341 (3150–6698) 40 (0–141)
36 4233 (3002–5980) 0 (0–55)
42 3967 (2983–5868) 0 (0–110)
48 3687 (2674–5469) 0 (0–0)
54 3363 (2419–4797) 0 (0–0)
60 3334 (2452–4820) 0 (0–0)
66 3129 (1987–4632) 0 (0–0)
72 2959 (2017–4143) 0 (0–0)

Values are median (interquartile range). Acetaminophen levels were higher in the acetaminophen arm compared with the control arm at all time points (P < .001 for all comparisons), except for enrollment when concentrations were higher in the control arm (P = .014).