Skip to main content
. 2022 Sep 30;13:973655. doi: 10.3389/fendo.2022.973655

Table 4.

Comparison of the ability of TyG to predict β-cell dysfunction.

Variable AUC (95% CI) Cut-off Sensitivity Specificity Youden index P-value
Early-phase β-Cell dysfunction indices
I30/I0 Ratio DI 0.71 (0.67-0.75) 9.17     0.75    0.6 0.35 <0.001
CP30/CP0 ratio DI 0.73 (0.69-0.77) 9.31     0.71    0.68 0.39 <0.001
△I30/△G30 ratio DI 0.68 (0.64-0.72) 9.08     0.76    0.53 0.28 <0.001
△CP30/△G30 ratio DI 0.70 (0.66-0.74) 9.19     0.71    0.68 0.34 <0.001
CIR30x10-2 DI 0.74 (0.71-0.78) 9.31     0.7    0.68 0.37 <0.001
Stumvoll first phase
x10-2 DI
0.65 (0.61-0.69) 9.36     0.55    0.67 0.22 <0.001
Late-phase β-Cell dysfunction indices
I120/I0ratio DI 0.67 (0.63-0.72) 9.31     0.65    0.67 0.32 <0.001
CP120/CP0 ratio DI 0.71 (0.67-0.75) 9.31     0.7    0.69 0.38 <0.001
△I120/△G120 ratio DI 0.63 (0.58t-.67) 9.31     0.6    0.65 0.24 <0.001
△CP120/△G120 ratio DI 0.63 (0.58-0.67) 9.35     0.57    0.67 0.24 <0.001
CIR120x10-2DI 0.74 (0.70-0.77) 9.2     0.76    0.62 0.38 <0.001
Stumvoll second phase x10-2 DI 0.72 (0.68-0.75) 9.36     0.63    0.7 0.33 <0.001