Skip to main content
. 2022 Oct 14;12:17251. doi: 10.1038/s41598-022-22091-6

Table 3.

OCT-Angiography parameters.

OCT-A parameters XEN stent TE p-value
Macular OCT-A
FAZ in mm2 0.57 ± 0.29 0.59 ± 0.30 0.781b
VAD in % 29.0 ± 2.2 30.3 ± 3.6 0.163c
SSI 30.5 ± 3.7 30.7 ± 4.3 0.918c
Optic disc OCT-A
VAD in % 36.3 ± 1.7 37.1 ± 2.4 0.206c
Peripapillary OCT-A
VAD SVC 375 µm in % 37.0 ± 6.3 40.1 ± 5.5 0.123c
VAD DVC 375 µm in % 33.5 ± 3.0 35.0 ± 2.6 0.117c
VAD CCL 375 µm in % 34.0 ± 4.6 37.3 ± 5.4 0.050c
VAD CL 375 µm in % 36.0 ± 4.3 39.7 ± 4.7 0.013c
VAD SVC 750 µm in % 36.1 ± 5.3 38.8 ± 5.5 0.157c
VAD DVC 750 µm in % 31.7 ± 2.5 32.6 ± 2.1 0.267c
VAD CCL 750 µm in % 33.9 ± 3.1 35.5 ± 4.1 0.178c
VAD CL 750 µm in % 35.7 ± 3.0 38.1 ± 2.6 0.028c
SSI 31.1 ± 3.7 30.1 ± 2.6 0.444c

Significant values are in bold.

Differences between the groups are shown as mean ± standard deviation.

FAZ foveal avascular zone, VAD vessel area density, SSI Signal Strength Index, SVC superficial vascular complex, DVC deep vascular complex, CCL choriocapillaris layer, CL chorioideal layer, 375 µm radius around optic disc, 750 µm radius around optic disc.

aChi-Quadrat test.

bMann-Whitney U test.

ct test.