Table 8.

Measurement results under DN1600 pipe diameter.

Flow Velocity Point (m/s) Standard Flow (m3/h) Measured Flow (m3/h) Relative
Indication Error of a Single
Point (%)
Average value
of Relative
Indication
Error (%)
Repeat-ability
(%)
1.51 10947.600 10875.600 −0.658 −0.615 0.037
10929.600 10864.800 −0.593
10886.400 10821.600 −0.595
1.34 9694.800 9640.800 −0.557 −0.643 0.150
9712.800 9633.600 −0.815
9720.000 9666.000 −0.556
1.18 8528.400 8478.000 −0.591 −0.548 0.043
8542.800 8499.600 −0.506
8546.400 8499.600 −0.548
0.98 7059.600 7012.800 −0.663 −0.645 0.078
7074.000 7023.600 −0.712
7066.800 7027.200 −0.560
0.81 5868.000 5828.400 −0.675 −0.695 0.094
5871.600 5824.800 −0.797
5878.800 5842.800 −0.612