Skip to main content
. Author manuscript; available in PMC: 2023 Oct 1.
Published in final edited form as: FASEB J. 2022 Oct;36(10):e22521. doi: 10.1096/fj.202200033R

Table 1.

Laser parameter setting.

Parameter No. Beam spot size (cm2) Exposure duration (s) 1064 nm laser 1270 nm laser
Irradiance at target (W/cm2) Radiant exposure (J/cm2) Radiant energy (J) Total radiant energy (J) Irradiance at target (W/cm2) Radiant exposure (J/cm2) Radiant energy (J) Total radiant energy (J)
1 0.32 60 0.300 18.0 5.76 23.0 - - - -
2 0.32 60 0.350 21.0 6.72 26.9 - - - -
3 0.32 60 - - - - 0.050 3.00 0.96 3.84
4 0.32 60 0.300 18.0 5.76 23.0 0.050 3.00 0.96 3.84
5 0.32 60 0.150 9.00 2.88 11.5 0.050 3.00 0.96 3.84
6 0.32 60 0.300 18.0 5.76 23.0 0.100 6.00 1.92 7.68
7 0.20 60 3.00 180 36.0 180 1.00 60.0 12.0 60.0
8 0.20 60 3.00 180 36.0 180 0.50 30.0 6.00 30.0
9 0.20 30 6.00 180 36.0 180 1.00 30.0 6.00 30.0
10 0.20 60 1.50 90.0 18.0 90.0 0.25 15.0 3.00 15.0
11 0.20 120 1.50 180 36.0 180 0.25 30.0 6.00 30.0
12 0.20 60 3.00 180 36.0 36.0 1.00 60.0 12.0 12.0
13 0.20 60 3.00 180 36.0 36.0 0.50 30.0 6.00 6.00
14 0.20 120 1.50 180 36.0 36.0 0.25 30.0 6.00 6.00
15 0.20 120 6.00 720 144 144 1.00 120 24.0 24.0

Laser parameters used in following each experiment in this study are summarized in this Table.

Figure 1, S2: Parameter 1–4

Figure 2: Parameter 5–6

Figure 3, S3: Parameter 12–15

Figure 4, S4, S5: Parameter 7–11

Figure 5: Parameter 4

Figure 6, 7, S6, S7: Parameter 7, 10