Skip to main content
. 2022 Oct 18;36:101516. doi: 10.1016/j.tsep.2022.101516

Table 2.

Specifications of major components in the schematic layout.

Solar PTC
Location Kolkata (22–38-59 N, 88–27-00E)
Air heating load (kW) 18.65
Mean solar radiant energy (W/m2) 600
Collector aperture

Width, length (m) 5.77 [37], 22.18
Aperture area (m2) 128.1
Absorber tube:
Diameter, length (m) 0.066, 22.18
Optical efficiency 0.71 [37]
Thermal efficiency 0.41 [35]
Heat exchanger
Arrangement Counter-flow
Air mass flow (kg/s) 0.22
Overall heat coefficient, U (W/m2K) 296.5
Tube side
Heat convection constant (W/m2K) 1264.1
T1, T2 (°C) 30, 75
Tube diameter, length (m) 0.0158, 1.2
Number of tube/passes 30
Shell side
Heat convection constant (W/m2K) 387
T3, T4 (°C) 105, 60
Diameter, length (m) 0.6, 1.58
Internal volume (m3) 0.378
Number of baffles, spacing (m) 8, 0.12
Air cooler
Tube: surface area (m2) 4.22
Diameter, length (m) 0.016, 84
Fins: surface area (m2) 1.80