Skip to main content
. 2022 Oct 5;24(6):419. doi: 10.3892/ol.2022.13539

Table III.

Comparison of Con-RT and FLASH-RT.

Item Con-RT FLASH
Equipment Proton and ion accelerator, X-knife, γ-knife, Proton accelerators, linear accelerator
Cost Proven equipment, technology, research and clinical translation Higher technology cost, equipment cost, personnel cost, research cost, automation and clinical efficiency
Dose rate, Gy/sec 0.002-0.017 >40
Ray X- and γ-ray, proton, heavy ion, electron Proton, X-ray, electron
Time, sec ≥120 <1
Tumor control effect Efficient Efficient
Damage degree of normal tissue High Low
Factors Tissue radiosensitivity, dose Dose, dose segmentation, oxygen content, pulse
Mechanism Oxygen depletion hypothesis, ROS, immunoinflammatory hypothesis Repair, reoxygenation, redistribution, repopulation, oxygen depletion hypothesis, ROS

Con-RT, conventional radiotherapy; ROS, reactive oxygen species.