Table III.
Item | Con-RT | FLASH |
---|---|---|
Equipment | Proton and ion accelerator, X-knife, γ-knife, | Proton accelerators, linear accelerator |
Cost | Proven equipment, technology, research and clinical translation | Higher technology cost, equipment cost, personnel cost, research cost, automation and clinical efficiency |
Dose rate, Gy/sec | 0.002-0.017 | >40 |
Ray | X- and γ-ray, proton, heavy ion, electron | Proton, X-ray, electron |
Time, sec | ≥120 | <1 |
Tumor control effect | Efficient | Efficient |
Damage degree of normal tissue | High | Low |
Factors | Tissue radiosensitivity, dose | Dose, dose segmentation, oxygen content, pulse |
Mechanism | Oxygen depletion hypothesis, ROS, immunoinflammatory hypothesis | Repair, reoxygenation, redistribution, repopulation, oxygen depletion hypothesis, ROS |
Con-RT, conventional radiotherapy; ROS, reactive oxygen species.