TABLE 7.
Monocyte CD4 expression levels before and after overnight culture in adherent and nonadherent environments
Isolation no. | Monocyte CD4 expression (mean channel no.) in:
|
|||||||
---|---|---|---|---|---|---|---|---|
Whole blood (baseline)
|
Overnight PBMC cultures in:
|
|||||||
Gelatin-fibronectin-coated polystyrene flasks
|
Uncoated polystyrene flasks
|
Teflon vials
|
||||||
Autoa | CD4b | Auto | CD4 | Auto | CD4 | Auto | CD4 | |
18 | 0.276 | 5.33 | 0.324 | 0.200 | 0.440 | 0.253 | NDc | ND |
20 | 0.224 | 4.79 | 0.705 | 0.692 | 0.566 | 0.714 | ND | ND |
21 | 0.291 | 5.54 | 0.269 | 0.225 | 0.310 | 0.289 | ND | ND |
26 | 0.190d | 4.02d | 0.492 | 1.02 | 0.352 | 1.32 | 0.368 | 1.21 |
27 | 0.125d | 3.87d | 0.269 | 0.244 | 0.220 | 0.220 | 0.220 | 0.279 |
28 | 0.302 | 6.88 | 0.256 | 0.426 | 0.198 | 0.389 | 0.237 | 0.420 |
Meane ± SEM | 4.84 ± 0.43f | 0.082 ± 0.098g | 0.183 ± 0.166g | 0.361 ± 0.243b |
Mean channel number of autofluorescence (FL2 log).
Mean channel number of anti-CD4–PE signal.
ND, not done.
Whole-blood data not available due to Q-Prep malfunction; data from post-Ficoll-Paque PBMC are shown.
Corrected for autofluorescence.
Statistically significant CD4 expression relative to autofluorescence; P < 0.050.
Statistically significant decrease in CD4 expression relative to whole blood; P < 0.050.
Although the reduction in CD4 expression in Teflon-cultured monocytes compared to whole-blood monocytes did not quite reach statistical significance (P value, between 0.060 and 0.050), no statistically significant difference in CD4 expression between the three types of overnight cultures (P > 0.050) was observed.