Skip to main content
. 2022 Oct 20;12:17565. doi: 10.1038/s41598-022-21769-1

Table 3.

Parameter setting for EEMD-LSTM.

Modelling strategy Parameter name Description
EEMD Number of IMF 8
Amplitude of the added noise 0.2
LSTM Optimizer Adam
Number of LSTM unit 128, 128
Learning rate 0.00001
β12 0.9, 0.999
Activation function ReLU
Number of epochs 100
Batch size 128
Dropout 0.1
Loss function MSE