Skip to main content
. 2022 Oct 7;13:926491. doi: 10.3389/fendo.2022.926491

Table 4.

Diagnostic accuracy measures of MRI and CT as first imaging study in 2010–2017.

Sensitivity Specificity PPV NPV Positive LR Negative LR
Pancreatic head
MRI 65.2 (44.8–81.3) 100 (92.1–100) 100 (76.1–100) 87.1 (76.3–93.6) Inf 0.35 (0.20–0.61)
CT 27.3 (9.2–57.1) 90.5 (69.9–98.6) 60.0 (22.9–88.4) 70.4 (51.3–84.3) 2.86 (0.56–14.7) 0.80 (0.55–1.18)
Pancreatic body/tail
MRI 75.0 (56.4–87.6) 95.9 (85.5–99.6) 91.3 (72.0–98.8) 87.0 (75.3–93.9) 18.4 (4.7 – 72.6) 0.26 (0.14–0.50)
CT 77.8 (54.3–91.5) 100 (74.9–100) 100 (74.9–100) 77.8 (54.3–91.5) Inf 0.22 (0.09–0.53)

95% CIs are given in parentheses.

CT, computed tomography; LR, likelihood ratio; MRI, magnetic resonance imaging; NPV, negative predictive value; PPV, positive predictive value.