Table 2.
Variables Associated With a Faster Rate of Retinal Nerve Fiber Layer Thinning
Univariable Analysis | Multivariable Analysis | |||||
---|---|---|---|---|---|---|
Beta | 95% CI | P-Value | Beta | 95% CI | P-Value | |
Age, per 1 y older | 0.003 | −0.001, 0.008 | 0.170 | |||
Female sex | −0.064 | −0.204, 0.075 | 0.364 | |||
Highest IOP during the initial 6 mo, per 1 mm Hg higher | −0.057 | −0.068, −0.045 | <0.001 | −0.050 | −0.063, −0.037 | <0.001 |
Glaucoma surgery during the initial 6 mo | −0.445 | −0.626, −0.265 | <0.001 | −0.005 | −0.198, 0.188 | 0.957 |
Mean LCCI, per 1 unit larger | −0.060 | −0.084, −0.037 | <0.001 | −0.043 | −0.065, −0.020 | <0.001 |
Global CT, per 1 µm thicker | 0.001 | 0.000, 0.003 | 0.061 | 0.001 | 0.000, 0.003 | 0.018 |
VF MD, per 1 dB higher | −0.004 | −0.015, 0.008 | 0.545 | |||
VF PSD, per 1 dB higher | 0.009 | −0.008, 0.025 | 0.300 | |||
AXL, per 1 mm longer | −0.010 | −0.056, 0.035 | 0.653 | |||
CCT, per 1 µm thicker | −0.002 | −0.004, 0.001 | 0.060 | 0.000 | −0.002, 0.001 | 0.674 |
CI, confidence interval; IOP, intraocular pressure; LCCI, lamina cribrosa curve index; CT, choroidal thickness; VF, visual field; MD, mean deviation; PSD, pattern standard deviation; AXL, axial length; CCT, central corneal thickness.
Significant P values are in bold.