Table 3.

Organs at Risk Dosimetric Comparison between Both Radiotherapy Techniques

Organ Parameter 3D-CRT plan RapidArc plan P-value
Healthy Dmean (Gy) 25.2 ± 4.1 25.8 ± 4.6 0.071
brain volume D1% (Gy) 61.2 ± 2.5 57.4 ± 3.1 0.001
Brainstem Dmax (Gy) 52.6 ± 9.5 50.5 ± 18.1 0.648
Chiasma Dmax (Gy) 44.5 ± 13.4 41.8 ± 13.8 0.127
Ipsilateral optic nerve Dmax (Gy) 34.5 ± 17.1 31.6 ± 14.4 0.904
Contralateral optic nerve Dmax (Gy) 35.1± 19 31.7 ± 17.3 0.659
Ipsilateral Eye Dmean (Gy) 18.4 ± 11.6 15.5 ± 10.5 0.042
Contralateral Eye Dmean (Gy) 16.8 ± 14.1 13.1 ± 12.2 0.172
Ipsilateral Cochlea Dmean (Gy) 10.7 ± 13.4 5.9 ± 9.1 0.485
Contralateral Cochlea Dmean (Gy) 16.9 ± 21.1 8.6 ± 15.9 0.432
Ipsilateral Lens Dmax (Gy) 2.7 ± 2.3 2.9 ± 1.5 0.002
Contralateral Lens Dmax (Gy) 1.5 ± 2.1 1.6± 2.2 0.001