. 2022 Oct 24;24(12):2043–2056. doi: 10.1007/s11886-022-01799-x

Table 1.

Comparison of select continuous glucose monitors

Medtronic Guardian Sensor 3 Medtronic Guardian Sensor 4* Senseonics Eversense Dexcom G6 Abbott Freestyle Libre 2 Abbott Freestyle Libre 3
Sensor type rtCGM rtCGM rtCGM rtCGM isCGM rtCGM
Age of approval (years) 2+ 7+ 18+  2+ 4+ 4+
Subcutaneous or implanted Subcutaneous Subcutaneous

Surgically Implanted

Transmitter adhered to skin over implanted sensor

Subcutaneous Subcutaneous Subcutaneous
Duration of wear (days) 7 7 Maximum 180 10 14 14
Calibration status User calibration with blood glucose meter at least 2 × /day Factory calibrated User calibration with blood glucose meter 2 × /day Factory calibrated Factory calibrated Factory calibrated
Approved for use for insulin dosing No Yes Yes Yes Yes Yes
Compatible in HCL system MiniMed 670G, 770G MiniMed 780G No

Tandem t:slim X2 CIQ

Omnipod 5

CamAPS**

Diabeloop**

No No

References for Table 1 information: [25•, 138140]

rtCGM real-time continuous glucose monitor, isCGM intermittently scanned continuous glucose monitor, HCL hybrid closed loop, CIQ Control IQ

*At the time of writing, CE marked in Europe but still under review for United States FDA approval

**System not available in the USA