TABLE 3.
Assay characteristic | EIA
|
SIA
|
||||
---|---|---|---|---|---|---|
Ratio | % | 95% CIe | Ratio | % | 95% CI | |
Sensitivitya | 531/545 | 97.4 | 95.6–98.5 | 523/545 | 96.0 | 93.9–97.4 |
Specificityb | 1,024/1,029 | 99.5 | 98.8–99.8 | 1,027/1,029 | 99.8 | 99.2–100.0 |
Predictive value, positive testc | 531/536 | 99.1 | 97.7–99.7 | 523/525 | 99.6 | 98.5–99.9 |
Predictive value, negative testd | 1,024/1,038 | 98.7 | 97.7–99.2 | 1,027/1,049 | 97.9 | 96.8–98.6 |
Number of true-positive test results per total number of true positives.
Number of true-negative test results per total number of true negatives.
Number of true-positive test results per total number of positive test results.
Number of true-negative test results per total number of negative test results.
CI, confidence interval.