Skip to main content
. 2000 Sep;7(5):778–780. doi: 10.1128/cdli.7.5.778-780.2000

TABLE 3.

Results of the ImmunoWELL-IgM assay compared to results of the Remel EIA and CF assay

ImmunoWELL-IgM resultc Remel EIAa
CFb
No. (%) positive No. (%) negative No. (%) positive No. (%) negative
Positive 29 (45) 0 (0) 29 (45) 0 (0)
Negative 31 (48) 4 (6) 32 (50) 3 (5)
a

A single serum dilution was tested. A visible change in the membrane color in the test well to purple was considered positive. 

b

A standing titer of ≥64 or a fourfold rise in titer to ≥32 was considered positive. 

c

A single serum dilution was tested. Normalized optical density readings of ≥770 were considered positive.