Table 4.
PARAMETER | SYMBOL | TEST CONDITIONS |
VCC (V) | 25 °C | −40 °C TO 85 °C | −55 °C TO 125 °C | UNITS | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
VI (V) | VIS (V) | MIN | TYP | MAX | MIN | MAX | MIN | MAX | ||||
HC TYPES | ||||||||||||
High Level Input Voltage | VIH | - | - | 2 | 1.5 | - | - | 1.5 | - | 1.5 | - | V |
4.5 | 3.15 | - | - | 3.15 | - | 3.15 | - | V | ||||
6 | 4.2 | - | - | 4.2 | - | 4.2 | - | V | ||||
Low Level Input Voltage | VIL | - | - | 2 | - | - | 0.5 | - | 0.5 | - | 0.5 | V |
4.5 | - | - | 1.35 | - | 1.35 | - | 1.35 | V | ||||
6 | - | - | 1.8 | - | 1.8 | - | 1.8 | V | ||||
Maximum “ON” Resistance IO = 1 mA |
RON | VCC or GND |
VCC or GND |
4.5 | - | 70 | 160 | - | 200 | - | 240 | Ω |
6 | - | 60 | 140 | - | 175 | - | 210 | Ω | ||||
VCC to GND |
VCC to GND |
4.5 | - | 90 | 180 | - | 225 | - | 170 | Ω | ||
6 | - | 80 | 160 | - | 200 | - | 240 | Ω | ||||
Maximum “ON” Resistance Between Any Two Switches | ΔRON | - | - | 4.5 | - | 10 | - | - | - | - | - | Ω |
6 | - | 8.5 | - | - | - | - | - | Ω | ||||
Switch “Off” Leakage Current 16 Channels | IIZ | Ē = VCC | VCC or GND |
6 | - | - | ±0.8 | - | ±8 | - | ±8 | μA |
Logic Input Leakage Current | II | VCC or GND |
- | 6 | - | - | ±0.1 | - | ±1 | - | ±1 | μA |
Quiescent Device Current IO = 0 mA |
ICC | VCC or GND |
- | 6 | - | - | 8 | - | 80 | - | 160 | μA |