Table 1.
Exhaust fan on; air exchange rate (AER) in the bathroom: 10 h−1 | ||||||||
---|---|---|---|---|---|---|---|---|
Toilet only | Toilet + Sink | Toilet only | Toilet + Sink | Toilet only | Toilet + Sink | Toilet only | Toilet + Sink | |
Floor gap of bathroom door (Width × Height) | 81.28 cm × 0 cm (perfectly sealed door) | 81.28 cm × 2.54 cm | 81.28 cm × 5 cm | 81.28 cm × 2 m (door fully open) | ||||
Adjustment factor for ELA (a) | 1 | 0.66 | 0.5 | 0.025 | ||||
Exhaust Fan (QE, %) | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
Sink (a · Qs, %) | 0 | 11 | 0 | 7 | 0 | 5 | 0 | 0.003 |
Toilet (a · QT, %) | 100 | 89 | 66 | 59 | 50 | 45 | 0.025 | 0.022 |
ELA of door ((1 – a) · QD, %) | 0 | 0 | 34 | 34 | 50 | 50 | 0.975 | 0.975 |
Exhaust fan off; AER in the bathroom: 0.5 h−1 | ||||||||
Toilet only | Toilet + Sink | |||||||
Sink (QS, %) | 0 | 11 | ||||||
Toilet (QT, %) | 100 | 89 | ||||||
ELA of door (QD, %) | 100 | 100 |