Table 4.
Parameter | Value | Source | Description |
---|---|---|---|
A | see Figure 1 | Paper | Mean amplitude of PSPs |
A input | 1.924779612734342 mV (1.9 mV) | Code (paper) | Mean amplitude of PSPs for input connections |
V mean | –65 mV | Destexhe et al., 2001 | Mean membrane voltage of a neuron without input |
S RW | 66,825/N (60,000/N) | Code (paper) | Scaling parameter for recurrent connections |
S R W static | SRW/73 | Experiment | SRW for data-base circuit with static synapses |
S 1 | 14.85 (14) | Code (paper) | Scaling parameter for connections from stream 1 |
S 2 | 36.498 (33) | Code (paper) | Scaling parameter for connections from stream 2 |
w ex | Code | Maximum conductance for excitatory synapses | |
w in | Code | Maximum conductance for inhibitory synapses | |
b U | 0.5 | Paper | Factor defining the std. for the distribution of U |
b rec | 0.5 | Paper | Factor defining the std. for the distribution of τrec |
b fac | 0.5 | Paper | Factor defining the std. for the distribution of τfac |
b d | 0.1 | Code | Factor defining the std. for the distribution of d |
b w | 0.7 | Paper | Factor defining the std. for the distribution of wex and win |
The source column indicates where the value can be found, searching in the following order: main replicated paper, referenced papers, source code, own experiments. If a value was given in the paper which differs from the one used in the code, the paper value is written in parenthesis.